Cooling performance in a minichannel heat sink with different triangular pin-fins configurations

Zhao, Kai and Sun, Xiaoxia and Xia, Yuanqing and Li, Qiangqiang and Shen, Lili and Lin, Min (2023) Cooling performance in a minichannel heat sink with different triangular pin-fins configurations. Frontiers in Energy Research, 11. ISSN 2296-598X

[thumbnail of pubmed-zip/versions/2/package-entries/fenrg-11-1087501-r1/fenrg-11-1087501.pdf] Text
pubmed-zip/versions/2/package-entries/fenrg-11-1087501-r1/fenrg-11-1087501.pdf - Published Version

Download (3MB)

Abstract

With the continuous progress of automotive new energy technology, the motor has become an important part of the power system, and the heat dissipation of insulated-gate bipolar transistors (IGBT) determines the reliability of the power system. Minichannel structure can be added to the thermal management system of new energy vehicles to improve the heat transfer capacity. Due to the growth of the boundary layer in the smooth minichannel flow channel, the cooling performance improvement was limited. Pin-fins and rib structures were used to break the boundary layer and increased the heat transfer area to enhance the heat transfer capacity. In this study, a numerical simulation model of minichannel with triangular pin-fins with different rotation angles was established and calculated using the SST k-omega method. The temperature field, velocity field, pressure, and vortex distribution under different configurations were discussed in detail. The jet area formed by the prism wall and the side wall of the minichannel would impact the wall and reduce the growth of the boundary layer. However, the stagnation area generated in the center and corner will reduce the improvement of heat transfer capacity. The thermo-hydraulic characteristics of different configurations at different Reynolds numbers (Re), such as Nusselt number (Nu), Darcy friction resistance coefficient (f), and performance evaluation criterion (PEC), were analyzed. As Re increased, the best and worst configurations changed, the best configuration changed from the 90°–120° structure to the 120°–120° structure, and the worst configuration changed from the 75°–60° to the 60°–60° structure. When the Re = 663, the influence of the front and rear rotation angle on the cooling performance was explored. When the rotation angle was closer to 60°, the cooling performance of the minichannel was better. And the closer the rotation angle was to 120°, the cooling performance was better. This has a reference effect on the design of minichannel heat sinks.

Item Type: Article
Subjects: Euro Archives > Energy
Depositing User: Managing Editor
Date Deposited: 28 Apr 2023 04:10
Last Modified: 13 Jan 2024 03:46
URI: http://publish7promo.com/id/eprint/2412

Actions (login required)

View Item
View Item